ArcWriter Standard System Components:
• Dual-gas mechanized marking torch
• Power Supply
• Leads
• Arc voltage control board (optional)
• Current control panel (optional)
• Mounting and stand-off accessories (optional)
 
 ArcWriter Performance Data:
• Light Marking Will be clearly visible on the surface of the freshly scored plate.
• Heavy Marking and Scoring Will be clearly visible on the surface of the freshly scored playe. Dimensional characteristics controlled by adjusting current, gas type and marking speed.
• Punch Mark or Dimple Will be round with dimensional characteristics controlled by adjusting current, gas type and dwell time.
 
 ArcWriter Power Supply:
• Electrical  
     Rated OCV 235 VDC at rated input Voltage
     Output Current 4-19 amps, adjustable in 1-amp increments
     Output Voltage 120 VDC
     Duty Cycle at 40 ° C 100% (19 amps, 120 VDC)
     Input Voltage 200V, 3PH, 50-60Hz   ι   208V, 3PH, 60 Hz   ι 240V, 3PH, 60Hz   ι  400V, 3PH, 60Hz   ι  440V, 3PH, 60Hz   ι  480V, 3PH, 60Hz   ι  600V, 3PH, 50-60Hz
• Dimensions and Weight
     Depth 28.2 inches (716 mm)
     Width 12.6 inches (716 mm)
     Height 18.7 inches (716 mm)
     Weight 100 pounds (55 kg)
• Gas Requirements  
     Plasma Gas Air or H5 (premixed industrial grade gas containing 5% hydrogen and 95% Argon)
     Shield Gas Air
• Gas Quality  
     Air Clean, dry and oil-free
     H5 5% hydrogen, 95% Argon premixed
• Flow Rates and Pressures  
     Plasma Gas 60 scfh (28 I/min) @ 100 psi (6.9 bar) supplied to power supply pressure regulator
     H5 300 scfh (141 I/min) @ 100 psi (6.9 bar) supplied to power supply pressure regulator
 
 ArcWriter Plasma Torch:
Type Dual Gas, mechanized
Gas Plasma and Shield (refer to gas requirements)
Starting Method Contact Arc
Cap Sensor Pneumatic
Deminsions and Weight  
     Diameter 1.5 inches (38.1 mm)
     Length 11 inches (280 mm)
     Weight 1.5 pounds (0.8 kg)