Spirit 150a Torch: | ||
| • 150 amps @ 100% duty cycle | |||
| • Dual gass | |||
| • Liquid cooled | |||
| • Built in initial height sensing capability | |||
| • Extended life, low cost consumables | |||
| • Cutting and marking with the same consumables |
|||
| Spirit 150a Power Supply: | |||
| • Rated 150 amperes DC @ 100% duty cycle | |||
| • Advanced techology, high efficiency chopper-stabilized current output | |||
| • 400-ampere IGBT chopper transistors for high reliability | |||
| • Current overshoot reduction circuitry for longer electrode and nozzle life | |||
| • Very low transferred arc current sensing for higher starting height and longer nozzle shield life. |
|||
| • Fast switch transferred arc for extended nozzle life | |||
| • 70 GPH recirculating torch coolant system | |||
| • 0.4 amps pk - pk output current ripple at 200 amps | |||
| • 3-phase input, 41.4 KVA, 208v (174a), 230v (133a), 380v (81a), 415v (74a), 460v (67a), 575v (53a) |
|||
| • Sets all plasma torch paramaters by material type and thickness. | |||
| • Displays torch parts for selected material and thickness | |||
| • Communicates with optiona INOVA Torch Height Control and the x-v cutting Table control via RS-422 |
|||
| • Performs self diagnostics | |||
| • Sets optional INOVA Torch Height Control automatically to proper pierce height, cutting height and arc voltage |
|||
| • Tracks pierces, pierce errors and type of errors for the last six electrodes | |||
| • Extends electrode life through a patented process | |||
| • Software is updatable by 3.5" floppy | |||
| Spirit 200a Specifications: | |||||
|
Material |
Thickness (in.) (mm) |
Current (Amps) |
Speed (IPM) (m/min)** |
||
Mild Steel O2 Plasma O2 / Air Shield |
|||||
0.36 |
1.0 |
30 |
105 |
2.616 |
|
.060 |
1.5 |
30 |
78 |
2.021 |
|
.105 |
2.5 |
30 |
55 |
1.456 |
|
.125 |
3.0 |
50 |
180 |
4.660 |
|
.188 |
5.0 |
70 |
130 |
3.265 |
|
.250 |
6.0 |
100 |
150 |
3.952 |
|
.375 |
10.0 |
100 |
100 |
2.404 |
|
.500 |
12.0 |
100 |
65 |
1.850 |
|
.625 |
16.0 |
150 |
70 |
1.762 |
|
.750 |
20.0 |
150 |
55 |
1.340 |
|
1.00* |
25.0 |
150 |
40 |
1.040 |
|
1.25* |
32.0 |
150 |
25 |
0.624 |
|
1.50* |
38.0 |
150 |
15 |
0.385 |
|
Material |
Thickness (in.) (mm) |
Current (Amps) |
Speed (IPM) (m/min)** |
||
Stainless Steel Air Plasma Air / N2 Shield |
.036 |
1.0 |
30 |
200 |
4.857 |
.060 |
1.5 |
30 |
125 |
3.259 |
|
.105 |
2.5 |
50 |
75 |
2.082 |
|
.120 |
3.0 |
50 |
65 |
1.684 |
|
.188 |
5.0 |
70 |
100 |
2.447 |
|
.250 |
6.0 |
100 |
100 |
2.596 |
|
.375 |
10.0 |
100 |
80 |
1.935 |
|
.500 |
12.0 |
100 |
55 |
1.539 |
|
Material |
Thickness (in.) (mm) |
Current (Amps) |
Speed (IPM) (m/min)** |
||
Aluminum Air Plasma Air / N2 Shield |
.040 |
1.0 |
30 |
150 |
3.886 |
.050 |
1.5 |
30 |
90 |
2.520 |
|
.063 |
1.5 |
50 |
180 |
3.868 |
|
.080 |
1.5 |
50 |
90 |
3.868 |
|
.188 |
5.0 |
70 |
80 |
1.921 |
|
.250 |
6.0 |
100 |
105 |
2.709 |
|
.375 |
10.0 |
100 |
90 |
2.208 |
|
.500 |
12.0 |
100 |
70 |
1.891 |
|
| *Requires edge start or moving pierce **Approximate Speed |
|||||