- Cutting Machines
- AutoFold Coil Lines
- Plasmas
- Torch Height Controls
- Used Equipment
![]() |
Spirit 200a Torch: |
| • 200 amps @ 100% duty cycle | |
| • Dual gass | |
| • Liquid cooled | |
| • Built in initial height sensing capability | |
| • Extended life, low cost consumables | |
| • Cutting and marking with the same consumables |
|
| Spirit 200a Power Supply: | |
| • Rated 200 amperes DC @ 100% duty cycle | |
| • Advanced techology, high efficiency chopper-stabilized current output | |
| • 400-ampere IGBT chopper transistors for high reliability | |
| • Current overshoot reduction circuitry for longer electrode and nozzle life | |
| • Very low transferred arc current sensing for higher starting height and longer nozzle shield life. |
|
| • Fast switch transferred arc for extended nozzle life | |
| • 70 GPH recirculating torch coolant system | |
| • 0.4 amps pk - pk output current ripple at 200 amps | |
| • 3-phase input, 41.4 KVA, 208v (174a), 230v (133a), 380v (81a), 415v (74a), 460v (67a), 575v (53a) |
|
| • 3 Year Warrenty | |
| Spirit 200a Automatic Gas Console: | |
| • Sets all plasma torch paramaters by material type and thickness. | |
| • Displays torch parts for selected material and thickness | |
| • Communicates with optiona INOVA Torch Height Control and the x-v cutting table control via RS-422 |
|
| • Performs self diagnostics | |
| • Sets optional INOVA Torch Height Control automatically to proper pierce height, cutting height and arc voltage |
|
| • Tracks pierces, pierce errors and type of errors for the last six electrodes | |
| • Extends electrode life through a patented process | |
| • Software is updatable by 3.5" floppy | |
| Spirit 200a Specifications: | |||||
Material |
Thickness (in.) (mm) |
Current (Amps) |
Speed (IPM) (m/min)** |
||
Mild Steel O2 Plasma Shield |
|||||
0.36 |
1.0 |
30 |
105 |
2.616 |
|
.060 |
1.5 |
30 |
78 |
2.021 |
|
.105 |
2.5 |
30 |
55 |
1.456 |
|
.125 |
3.0 |
50 |
180 |
4.660 |
|
.188 |
5.0 |
70 |
130 |
3.265 |
|
.250 |
6.0 |
70 |
120 |
3.105 |
|
.375 |
10.0 |
100 |
100 |
2.404 |
|
.500 |
12.0 |
150 |
90 |
2.485 |
|
.625 |
16.0 |
200 |
100 |
2.514 |
|
.750 |
20.0 |
200 |
75 |
1.811 |
|
1.00 |
25.0 |
200 |
50 |
1.310 |
|
1.25 |
32.0 |
200 |
25 |
0.626 |
|
1.50* |
38.0 |
200 |
17 |
0.435 |
|
1.75* |
45.0* |
200 |
12 |
0.293 |
|
2.00* |
50.0* |
200 |
7 |
0.193 |
|
Material |
Thickness (in.) (mm) |
Current (Amps) |
Speed (IPM) (m/min)** |
||
Stainless Steel Air Plasma / N2 Shield |
.036 |
1.0 |
30 |
200 |
4.857 |
.060 |
1.5 |
30 |
125 |
3.259 |
|
.105 |
2.5 |
50 |
75 |
2.082 |
|
.120 |
3.0 |
50 |
65 |
1.684 |
|
Material |
Thickness (in.) (mm) |
Current (Amps) |
Speed (IPM) (m/min)** |
||
Stainless Steel H17 Plasma / N2 Shield |
.188 |
5.0 |
70 |
80 |
2.032 |
.250 |
6.0 |
100 |
100 |
2.626 |
|
.375 |
10.0 |
150 |
75 |
1.874 |
|
.500 |
12.0 |
150 |
60 |
1.609 |
|
.625 |
16.0 |
200 |
60 |
1.513 |
|
.750 |
20.0 |
200 |
50 |
1.213 |
|
1.00 |
25.0 |
200 |
35 |
0.913 |
|
Material |
Thickness (in.) (mm) |
Current (Amps) |
Speed (IPM) (m/min)** |
||
Aluminum Air plasma/N2 Shield |
.040 |
1.0 |
30 |
150 |
3.886 |
.050 |
1.5 |
30 |
120 |
2.520 |
|
.063 |
1.5 |
50 |
140 |
3.868 |
|
.080 |
1.5 |
50 |
90 |
3.868 |
|
.125 |
3.0 |
70 |
160 |
4.419 |
|
.188 |
5.0 |
70 |
80 |
1.921 |
|
.250 |
6.0 |
70 |
50 |
1.442 |
|
.375 |
10.0 |
100 |
90 |
2.208 |
|
.500 |
12.0 |
150 |
90 |
2.428 |
|
.625 |
16.0 |
200 |
95 |
2.382 |
|
.750 |
20.0 |
200 |
65 |
1.538 |
|
1.00 |
25.0 |
200 |
35 |
0.937 |
|
| *Requires edge start or moving pierce **Approximate Speed |
|||||